DIRECTIONAL SPOOL VALVE 4WE6L6X/EW230N9DAL/62
Size 6, symbol L, electrical with solenoid, 230 V AC 50/60 Hz
Industrial hydraulic valve in a high performance range. Reliable switching of the oil flow direction according to hydraulic symbol.
Unpacked Weight: 1.8 kg
4/3-, 4/2- or 3/2-way version Porting pattern according to ISO4401-03-02-0-05 (with or without locating hole) High-power solenoid, optionally rotatable by 90° Electric connection as single or central connection Optional auxiliary operating device Spool position monitoring, optional CE conformity according to the Low-Voltage Directive 2014/35/EU for electrical voltages >50VAC or >75VDC Solenoid coil as approved component with UR marking according to UL906, edition 1982, optional Approval according to CSA C22.2 no. 139-1982, optional
Directional valves type WE are solenoid-operated directional spool valves and can be used as electromagnetic components. They control the start, stop and direction ofa flow.
The directional valves essentially consist of the housing (1), one or two electromagnets (2), the control spool (3) and the return springs (4).
In the de-energized state, the control spool (3) is held in the middle or initial position by the return springs (4) (except version “O”).
When the electromagnet (2) switching in oil is energized, the control spool (3) moves from its rest position to the desired end position. This releases the required flow direction according to the selected symbol.
After switching off the electromagnet (2), the control spool (3) is pushed back to the middle or initial position (except for valve with detent “OF” and valve without spring type “O”).
An auxiliary actuation (5) enables the valve to be switched manually without magnet supply.
The hydraulic system must be properly vented to ensure proper function.
Without spring return “O” (only possible with symbols A, C and D)
This version isa directional valve with two switching positions and two electromagnets without detent. The valve without spring return on the control spool (3) has no defined basic position when de-energized.
Without spring return with detent “OF” (only possible for symbols A, C and D)
This version is a directional valve with two switching positions and two electromagnets with detent. The control spool (3) is fixed in the respective switching position by the detents. During operation, the permanent current supply to the electromagnet can thus be omitted, which contributes to energy-efficient operation.
Version “.73...A12” (soft switching behavior)
The composition of the control spools and solenoids greatly reduces the number of switching strokes that occur when the valves are switched on or off. The switching strokes, measured as acceleration valuesa, can be reduced by approx. 85% compared to the standard valve, depending on the version of the control spool (see “Acceleration values”).
Notices:
Pressure peaks in the drain line to two or more valves may cause unintentional control spool movements in the version with detent. It is recommended to lay separate return lines or to install a check valve in the drain line.
Due to the design principle, the valves are subject to internal leakage, which can increase during the service life.
Type 4WE 6 E6X/...E...
Throttle insert
The use of a throttle insert is required when, due to prevailing operating conditions, flows occur during the switching processes which exceed the performance limit of the valve.
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | ||
WE | 6 | 6X | / | E | / | * |
01 | 3main ports | 3 | ||||||||
4main ports | 4 | |||||||||
02 | Directional valve | WE | ||||||||
03 | Size 6 | 6 | ||||||||
04 | Symbols; for the possible version, see "Symbols/Circuit diagrams" | |||||||||
05 | Component series 60…69 (60…69: unchanged installation and connection dimensions) | 6X | ||||||||
06 | With spring return | nocode | ||||||||
Without spring return | O | |||||||||
Without spring return with detent | OF | |||||||||
07 | High-power solenoid, wet-pin, with detachable coil | E | ||||||||
Electrical voltages | ||||||||||
08 | For ordering code see "Electrical connections and available voltages" below. | e.g.G24 | ||||||||
Manual override 1) | ||||||||||
09 | Without manual override | nocode | ||||||||
With manual override | N 3) | |||||||||
With manual override "mushroom button" (small) | N2 3) | |||||||||
With lockable manual override "mushroom button" (small) | N4 2; 3) | |||||||||
With lockable manual override "mushroom button" (large) | N5 2); 3; 4) | |||||||||
With manual override "mushroom button" (large), not lockable | N6 3; 4) | |||||||||
With lockable manual override "nut" | N72; 3) | |||||||||
With concealed manual override (standard) | N9 | |||||||||
Corrosion resistance (outside) (for the availability, refer to the following table) | ||||||||||
10 | None (valve housing primed) | nocode | ||||||||
Improved corrosion protection (240h salt spray test according to ENISO9227) | J3 | |||||||||
High corrosion protection (720h salt spray test according to ENISO9227) | J5 | |||||||||
Electrical connection | ||||||||||
11 | Individual connection or central connection | |||||||||
For ordering code see "Electrical connections and available voltages" below. | e.g.K4 | |||||||||
Spool position monitoring (For more information, see data sheet 24830) | ||||||||||
12 | Without position switch | nocode | ||||||||
Inductive position switch type QM (valves with 2 spool positions) | ||||||||||
Monitored spool position "a" | QMAG24 | |||||||||
Monitored spool position "b" | QMBG24 | |||||||||
Monitored rest position | QM0G24 | |||||||||
Inductive position switch typeQR (valves with 3 spool positions) | ||||||||||
Monitored rest position | QM0G24 | |||||||||
Monitored spool position "a" and "b" | QRABG24E | |||||||||
Inductive position switch type QS | ||||||||||
Monitored spool position "a" | QSAG24W | |||||||||
Monitored spool position "b" | QSBG24W | |||||||||
Monitored spool position "0" | QS0G24W | |||||||||
Monitored spool position "0" and "a" | QS0AG24W | |||||||||
Monitored spool position "0" and "b" | QS0BG24W | |||||||||
Monitored spool position "a" and "b" | QSABG24W | |||||||||
Switching time increase | ||||||||||
13 | Without switching time increase | nocode | ||||||||
With switching time increase (only with direct voltage and only with version "N9" and symbol "73") | A12 | |||||||||
Throttle insert | ||||||||||
14 | Without throttle insert (standard) | nocode | ||||||||
With throttle insert (when the admissible valve performance limit is exceeded, refer to "Performance limits"): | ||||||||||
Connection | Throttle Ø inmm | |||||||||
0,6 mm | 0,8 mm | 1,0 mm | 1,2 mm | 1,5 mm | 2,0 mm | 2,5 mm | 3,0 mm | 4,0 mm | ||
P | = B06 | = B08 | = B10 | = B12 | = B15 | = B20 | = B25 | = B30 | = B40 | |
A | = H06 | = H08 | = H10 | = H12 | = H15 | = H20 | = H25 | = H30 | = H40 | |
B | = R06 | = R08 | = R10 | = R12 | = R15 | = R20 | = R25 | = R30 | = R40 | |
A and B | = N06 | = N08 | = N10 | = N12 | = N15 | = N20 | = N25 | = N30 | = N40 | |
T | = X06 | = X08 | = X10 | = X12 | = X15 | = X20 | = X25 | = X30 | = X40 | |
Clamping length | ||||||||||
15 | 42mm (standard) | nocode | ||||||||
22mm | Z | |||||||||
Control spool play | ||||||||||
16 | Standard (recommended) | nocode | ||||||||
Minimum (selection for reduced leakage values; higher oil cleanliness required) | T06 | |||||||||
Increased (selection with high temperature difference hydraulic fluid/environment; leads to higher internal leakage values) | T12 | |||||||||
Seal material (observe compatibility ofseals with hydraulic fluid used, see "Technical data") | ||||||||||
17 | NBR seals | nocode | ||||||||
FKM seals | V | |||||||||
Recommended for operation with HFC hydraulic fluids together with high temperatures | MH | |||||||||
Low-temperature version (only with version "Without manual override") | MT | |||||||||
18 | Standard | nocode | ||||||||
Solenoid coil as approved component with UR marking according to UL906, edition 1982 5) | = UR | |||||||||
Approval according to CSA C22.2 no. 139-1982 | = CSA | |||||||||
Porting pattern according to ANSIB93.9 6) | = AN | |||||||||
19 | Without locating hole | nocode | ||||||||
With locating hole and locking pin ISO8752-3x8-St | /62 | |||||||||
20 | Standard | nocode | ||||||||
With reduced electric power consumption (only versions "G24" as well as "K4", "DL" and "DKL") | SO407 | |||||||||
21 | Further details in the plain text | * |
1) | Operation of the manual override only possible up to 50 bar [725 psi] tank pressure. Avoid damage to the bore of the manual override. (Special tool for the operation, separate order, material no. R900024943). If the manual override is blocked, operation of the opposite solenoid is to be excluded. The manual override cannot be allocated a safety function. |
2) | With tank pressures higher than 50bar, it is not guaranteed that the valve remains in the position into which it was switched by the lockable manual override ("N4", "N5", "N7"). |
3) | Only direct voltage; not for version "= UR" |
4) | Only direct voltage; not for version "SO407" |
5) | Only for version "K4" with "G12", "G24" and "W110" |
6) | With power supply to -solenoid "a", channel P is connected to a -solenoid "b", channel P is connected to B |
Available corrosion resistance
Electrical connection | Manual override | ||||||||
"K4" | "DL" | "K40", "C4" | |||||||
"G12" | "G24" | "G24" | "G48" | "G12" | "G24" | "G26" | Ohne | "N" | |
"J3" | ✔ | ✔ | ✔ | ✔ | - | - | - | ✔ | ✔ |
"J5" | - | - | - | - | ✔ | ✔ | ✔ | ✔ | ✔ |
Electrical connections and available voltages
(special voltages upon request)
DC voltage – individual connection
Connector | Ordering code | Electrical voltages | Protection class according to DINEN60529 1) | Protection class according to VDE0580 | |||||||||
12V | 24V | 26V | 48V | 96V | 110V | 125V | 205V | 220V | |||||
Ordering code | |||||||||||||
G12 | G24 | G26 | G48 | G96 | G110 | G125 | G205 | G220 | |||||
3-pole connector (2+PE) according to DINEN175301-803 | Standard | K4 | ✔ | ✔ | - | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | IP65 | I 2) |
With potted-in plug base and sealing element | K4K | ✔ | ✔ | ✔ | - | - | - | - | - | - | IP65 | I 2) | |
Connector 2-pole, DT04-2PA (Deutsch type) | K40 | ✔ | ✔ | ✔ | - | - | - | - | - | - | IP65 | III 3) | |
Connector, 4-pole, M12x1 according to DINEN61076-2-101, with suppressor diode, coding A | Pin assignment according to DESINA | K72L | - | ✔ | - | - | - | - | - | - | - | IP65 | III 3) |
Standard | K73L | - | ✔ | - | - | - | - | - | - | - | IP65 | III 3) | |
Connector 2-pole (Junior-Timer type) | Connector parallel to the valve axis | C4 | ✔ | ✔ | ✔ | - | - | - | - | - | - | IP65 | III 3) |
Maximum admissible overvoltages according to DINEN60664-1:2008-01 (VDE0110-1) (overvoltage category II): | |||||||||||||
Nominal voltage UNom | V | 12 | 24 | 26 | 48 | 96 | 110 | 125 | 205 | 220 | |||
Rated current INom | A | 2,5 | 1,25 | 1,17 | 0,66 | 0,33 | 0,25 | 0,17 | 0,16 | 0,14 | |||
Maximum admissible switch-off overvoltage according to VDE0580 | V | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |||
Recommended interference protection circuit with 2 x mains voltage | V | 24 | 48 | 52 | 96 | 192 | 220 | 250 | 410 | 440 |
1) | Only with correctly mounted valve with a mating connector suitable for the protection class. |
2) | Protection class I with properly connected protective grounding conductor (PE) and valve mounting surface connected to the protective grounding conductor system. |
3) | With protection class III, a protective extra-low voltage with isolation transformer (PELV, SELV) is to be provided. |
Notice:
Solenoid valves induce voltage peaks during switch-off. In order to prevent electro-magnetic interference at the system and damage to the valve control, an interference protection circuit has to be provided on the system side. Alternatively, you can also select a connector with integrated interference protection circuit.
DC voltage - central connection
Connector | Ordering code | Electrical voltages | Protection class according to DINEN60529 1) | Protection class according to VDE0580 | |||||||
12V | 24V | 48V | 96V | 110V | 125V | 220V | |||||
Ordering code | |||||||||||
G12 | G24 | G48 | G96 | G110 | G125 | G220 | |||||
Cable gland, terminal area 6 … 12mm | With indicator light | DL | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | IP65 | I 2) |
With indicator light and interference protection circuit | DL1 | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | IP65 | I 2) | |
Cable gland, threaded connection 1/2"-14 NPT | With indicator light | DAL | ✔ | ✔ | - | - | - | ✔ | - | IP65 | I 2) |
With indicator light and interference protection circuit | DAL1 | ✔ | ✔ | - | - | - | ✔ | - | IP65 | I 2) | |
7-pole connector (6+PE) according to DINEN175201-804 | With indicator light | DK6L | - | ✔ | ✔ | - | ✔ | ✔ | ✔ | IP65 | I 2) |
With indicator light and interference protection circuit | DK6L1 | - | ✔ | ✔ | - | ✔ | ✔ | ✔ | IP65 | I 2) | |
Connector according to ANSI/B93.55M-1981 (Brad Harrison Mini-Change) | With indicator light, 3-pole | DK23L | - | ✔ | - | - | - | - | - | IP65 | I 2) |
With indicator light, 5-pole | DK25L | - | ✔ | - | - | - | - | - | IP65 | I 2) | |
Connector, 4-pole, M12x1 according to DINEN61076-2-101 | With indicator light | DK24L | - | ✔ | - | - | - | - | - | IP65 | III 3) |
With indicator light and interference protection circuit | DK24L1 | - | ✔ | - | - | - | - | - | IP65 | III 3) | |
With indicator light and interference protection circuit | DK35L | - | ✔ | - | - | - | - | - | IP65 | III 3) | |
Maximum admissible overvoltages according to DINEN60664-1:2008-01 (VDE0110-1) (overvoltage category II): | |||||||||||
Nominal voltage UNom | V | 12 | 24 | 48 | 96 | 110 | 125 | 220 | |||
Rated current INom | A | 2,5 | 1,25 | 0,66 | 0,33 | 0,25 | 0,17 | 0,14 | |||
Maximum admissible switch-off overvoltage according to VDE0580 | V | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |||
Recommended interference protection circuit with 2 x mains voltage | V | 24 | 48 | 96 | 192 | 220 | 250 | 440 |
1) | Only with correctly mounted valve with a mating connector suitable for the protection class. |
2) | Protection class I with properly connected protective grounding conductor (PE) and valve mounting surface connected to the protective grounding conductor system. |
3) | With protection class III, a protective extra-low voltage with isolation transformer (PELV, SELV) is to be provided. |
Notice:
Solenoid valves induce voltage peaks during switch-off. In order to prevent electro-magnetic interference at the system and damage to the valve control, an interference protection circuit has to be provided on the system side. Alternatively, you can also select a connector with integrated interference protection circuit.
Alternating voltage – individual connection
Connector | Ordering code | Electrical voltages | Protection class according to DINEN60529 1) | Protection class according to VDE0580 | ||||||||||
100V50/60Hz | 100V50/60Hz | 110V50/60Hz | 110V50/60Hz | 120V60Hz | 120V60Hz | 200V50Hz | 200V50Hz | 230V50/60Hz | 230V50/60Hz | |||||
Ordering code | ||||||||||||||
G96 | W110 | G96 | W110 | G110 | W110 | G180 | W200 | G205 | W230 | |||||
3-pole connector (2+PE) according to DINEN175301-803 | Standard | K4 | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | IP65 | I 2) |
Rectifier required (see "Accessories") | ✔ | ✔ | ✔ | - | ✔ | - | ✔ | - | ✔ | - | ||||
Maximum admissible overvoltages according to DINEN60664-1:2008-01 (VDE0110-1) (overvoltage category II): | ||||||||||||||
Nominal voltage UNom | V | 100 | 100 | 110 | 110 | 120 | 120 | 200 | 200 | 230 | 230 | |||
Rated current INom | 50~^&@@&^~Hz | A | 0,31 | 0,56 | 0,34 | 0,52 | - | - | 0,18 | 0,29 | 0,16 | 0,23 | ||
60~^&@@&^~Hz | A | 0,31 | 0,44 | 0,34 | 0,39 | 0,30 | 0,45 | - | - | 0,16 | 0,17 | |||
Lower rated current | 50~^&@@&^~Hz | A | - | 0,65 | - | 0,6 | - | - | - | 0,33 | - | 0,27 | ||
60~^&@@&^~Hz | A | - | 0,51 | - | 0,45 | - | 0,52 | - | - | - | 0,2 | |||
Upper rated current | 50~^&@@&^~Hz | A | - | 0,9 | - | 0,9 | - | - | - | 0,6 | - | 0,36 | ||
60~^&@@&^~Hz | A | - | 0,9 | - | 0,6 | - | 0,9 | - | - | - | 0,36 | |||
Maximum admissible switch-off overvoltage according to VDE0580 | V | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |||
Recommended interference protection circuit with 2 x mains voltage | V | 200 | 200 | 220 | 220 | 240 | 240 | 400 | 400 | 460 | 460 |
1) | Only with correctly mounted valve with a mating connector suitable for the protection class. |
2) | Protection class I with properly connected protective grounding conductor (PE) and valve mounting surface connected to the protective grounding conductor system. |
Notices:
Solenoid valves induce voltage peaks during switch-off. In order to prevent electro-magnetic interference at the system and damage to the valve control, an interference protection circuit has to be provided on the system side. Alternatively, you can also select a connector with integrated interference protection circuit. Depending on the rated current INom, circuit breakers according to tripping characteristic "K" are to be provided.
The tripping current must lie within a time interval of 0.6s with 8 to 10 times the nominal power supply.
The required non-tripping current of the fuse must not fall below the "lower rated current" value (see preceding table). The maximum tripping current must not exceed the "upper rated current" value (see preceding table).
The temperature dependence of the tripping behavior of the circuit breakers has to be considered according to the manufacturer's specifications.
Alternating voltage – central connection
Connector | Ordering code | Electrical voltages | Protection class according to DINEN60529 1) | Protection class according to VDE0580 | ||||||||
100~^&@@&^~V~^&@@&^~50/60~^&@@&^~Hz | 110V50/60Hz | 110V50/60Hz | 120V60Hz | 120V60Hz | 200V50Hz | 230V50/60Hz | 230V50/60Hz | |||||
Ordering code | ||||||||||||
W100 | W110R | W110 | W120R | W110 | W200 | W230R | W230 | |||||
Cable gland, terminal area 6 … 12mm | With indicator light | DL | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | IP65 | I 2) |
With indicator light and interference protection circuit | DL1 | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | IP65 | I 2) | |
With indicator light and interference protection circuit 3) | DJL | ✔ | - | - | - | - | ✔ | - | - | IP65 | I 2) | |
Cable gland, threaded connection 1/2"-14 NPT | With indicator light | DAL | ✔ | ✔ | ✔ | ✔ | ✔ | - | ✔ | ✔ | IP65 | I 2) |
With indicator light and interference protection circuit | DAL1 | - | ✔ | ✔ | ✔ | ✔ | - | ✔ | ✔ | IP65 | I 2) | |
7-pole connector (6+PE) according to DINEN175201-804 | With indicator light | DK6L | - | ✔ | ✔ | ✔ | ✔ | - | - | - | IP65 | I 2) |
With indicator light and interference protection circuit | DK6L1 | - | ✔ | ✔ | ✔ | ✔ | - | - | - | IP65 | I 2) | |
Connector according to ANSI/B93.55M-1981 (Brad Harrison Mini-Change) | With indicator light, 3-pole | DK23L | - | ✔ | ✔ | ✔ | ✔ | - | - | - | IP65 | I 2) |
With indicator light, 5-pole | DK25L | - | ✔ | ✔ | ✔ | ✔ | - | - | - | IP65 | I 2) | |
Maximum admissible overvoltages according to DINEN60664-1:2008-01 (VDE0110-1) (overvoltage category II): | IP65 | I 2) | ||||||||||
Nominal voltage UNom | V | 100 | 110 | 110 | 120 | 120 | 200 | 230 | 230 | |||
Rated current INom | 50~^&@@&^~Hz | A | 0,56 | 0,34 | 0,52 | - | - | 0,29 | 0,16 | 0,23 | ||
60~^&@@&^~Hz | A | 0,44 | 0,34 | 0,39 | 0,30 | 0,45 | - | 0,16 | 0,17 | |||
Lower rated current | 50~^&@@&^~Hz | A | 0,65 | - | 0,6 | - | - | 0,33 | - | 0,27 | ||
60~^&@@&^~Hz | A | 0,51 | - | 0,45 | - | 0,52 | - | - | 0,2 | |||
Upper rated current | 50~^&@@&^~Hz | A | 0,9 | - | 0,9 | - | - | 0,6 | - | 0,36 | ||
60~^&@@&^~Hz | A | 0,9 | - | 0,6 | - | 0,9 | - | - | 0,36 | |||
Maximum admissible switch-off overvoltage according to VDE0580 | V | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |||
Recommended interference protection circuit with 2 x mains voltage | V | 200 | 220 | 220 | 220 | 240 | 400 | 460 | 460 |
1) | Only with correctly mounted valve with a mating connector suitable for the protection class. |
2) | Protection class I with properly connected protective grounding conductor (PE) and valve mounting surface connected to the protective grounding conductor system. |
3) | Wire bridge between pin 2- and 4-. |
Notices:
Solenoid valves induce voltage peaks during switch-off. In order to prevent electro-magnetic interference at the system and damage to the valve control, an interference protection circuit has to be provided on the system side. Alternatively, you can also select a connector with integrated interference protection circuit. Depending on the rated current INom, circuit breakers according to tripping characteristic "K" are to be provided.
The tripping current must lie within a time interval of 0.6s with 8 to 10 times the nominal power supply.
The required non-tripping current of the fuse must not fall below the "lower rated current" value (see preceding table). The maximum tripping current must not exceed the "upper rated current" value (see preceding table).
The temperature dependence of the tripping behavior of the circuit breakers has to be considered according to the manufacturer's specifications.
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z4
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z45
Mating connectors for valves with connector “K4”, without circuitry, standard
3P Z45
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
Mating connectors for valves with connector “K4”, with indicator light
3P Z5L
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light
3P Z55L
Mating connectors for valves with connector “K4”, with indicator light
3P Z55L
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with rectifier
3P RZ5
Mating connectors for valves with connector “K4”, with rectifier
3P RZ5
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with rectifier
3P RZ55
Mating connectors for valves with connector “K4”, with rectifier
3P RZ55
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
Mating connectors for valves with connector “K4”, with indicator light and Zener diode suppression circuit
3P Z5L1
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light and rectifier
3P RZ5L
Mating connectors for valves with connector “K4”, with indicator light and rectifier
3P RZ5L
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for valves with connector “K4”, with indicator light and rectifier
3P RZ55L
Mating connectors for valves with connector “K4”, with indicator light and rectifier
3P RZ55L
For valves with connector “K4” according to EN175301-803 and ISO4400, 2-pole + PE, “large cubic connector” Mating connectors for valves with one or two solenoids (individual connection)
Data sheet
Spare parts & repair
Mating connectors for directional valves with connector "C4" and "C4Z" (AMP Junior-Timer), litz wire outer diameter 2.2 mm to 3.0 mm
2P JUNIOR D2 2
Mating connectors for directional valves with connector "C4" and "C4Z" (AMP Junior-Timer), litz wire outer diameter 2.2 mm to 3.0 mm
2P JUNIOR D2 2
For directional valves with connector "C4" and "C4Z" (AMP Junior-Timer)
Data sheet
Spare parts & repair
Mating connectors for directional valves with connector "C4" and "C4Z" (AMP Junior-Timer), litz wire outer diameter 1.2 mm to 2.1 mm
2P D1.2 JUNIOR
Mating connectors for directional valves with connector "C4" and "C4Z" (AMP Junior-Timer), litz wire outer diameter 1.2 mm to 2.1 mm
2P D1.2 JUNIOR
For directional valves with connector "C4" and "C4Z" (AMP Junior-Timer)
Data sheet
Spare parts & repair
Mating connectors for directional valves with connector "K40" (Deutsch plug)
2P DT06 K40
Mating connectors for directional valves with connector "K40" (Deutsch plug)
2P DT06 K40
For directional valves with "K40" connector (Deutsch plug)
Data sheet
Spare parts & repair
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1
4P Z24
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1
4P Z24
For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75mm2
Data sheet
Spare parts & repair
Mating connectors for mechanical position switches, mechanical pressure switches and valves with central connection with connector “K6” and “DK6L”, 6-pole + PE
7P Z6
Mating connectors for mechanical position switches, mechanical pressure switches and valves with central connection with connector “K6” and “DK6L”, 6-pole + PE
7P Z6
Mating connectors for mechanical position switches, mechanical pressure switches and valves with central connection with connector “K6”
Data sheet
Spare parts & repair
Connector switching amplifier
VT-SSBA1-PWM-1X
Connector switching amplifier
VT-SSBA1-PWM-1X
Data sheet
Spare parts & repair